Range of product | Harmony Timer Relays |
---|---|
Discrete output type | Relay |
Product or component type | Modular timing relay |
Device short name | RE22 |
nominal output current | 8 A |
Contacts type and composition | 1 C/O timed contact, cadmium free |
---|---|
Time delay type | Off-delay |
Time delay range | 10…100 s 3…30 s 0.05…1 s 30…300 s 30…300 h 30…300 min 3…30 min 3…30 h 0.3…3 s 1…10 s |
Control type | Rotary knob Diagnostic button Potentiometer external |
[Us] rated supply voltage | 24…240 V AC/DC 50/60 Hz |
Release input voltage | <= 2.4 V |
Voltage range | 0.85…1.1 Us |
Supply frequency | 50…60 Hz +/- 5 % |
Connections – terminals | Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end |
Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
Housing material | Self-extinguishing |
Repeat accuracy | +/- 0.5 % conforming to IEC 61812-1 |
Temperature drift | +/- 0.05 %/°C |
Voltage drift | +/- 0.2 %/V |
Setting accuracy of time delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
Time delay type | Off-delay – C- Off-delay relay w/ control signal Off-delay – Ct- Off-delay relay w/ control signal and pause/summation |
Control signal pulse width | 100 ms with load in parallel 30 ms |
Insulation resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
Recovery time | 120 ms on de-energisation |
Immunity to microbreaks | 10 ms |
Power consumption in VA | 3 VA at 240 V AC |
Power consumption in W | 1.5 W at 240 V DC |
Switching capacity in VA | 2000 VA |
Minimum switching current | 10 mA at 5 V DC |
Maximum switching current | 8 A |
Maximum switching voltage | 250 V AC |
Electrical durability | 100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1 |
Mechanical durability | 10000000 cycles |
Rated impulse withstand voltage | 5 kV for 1.2…50 µs conforming to IEC 60664-1 |
Power on delay | 100 ms |
Creepage distance | 4 kV/3 conforming to IEC 60664-1 |
Overvoltage category | III conforming to IEC 60664-1 |
Safety reliability data | MTTFd = 205.4 years B10d = 190000 |
Mounting position | Any position |
Mounting support | 35 mm DIN rail conforming to IEC 60715 |
Status LED | LED backlight green (steady) for dial pointer indication LED yellow (steady) for output relay energised LED yellow (fast flashing) for timing in progress and output relay de-energised LED yellow (slow flashing) for timing in progress and output relay energised |
Function available | C- Off-delay relay w/ control signal-1 C/O Ct- Off-delay relay w/ control signal and pause/summation-1 C/O |
Width | 22.5 mm |
Net weight | 0.1 kg |
control type | With test button |
Number of functions | 2 |
Dielectric strength | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1 |
---|---|
Standards | UL 508 IEC 61812-1 |
Directives | 2004/108/EC – electromagnetic compatibility 2006/95/EC – low voltage directive |
Product certifications | UL CE CCC CSA GL RCM EAC |
Ambient air temperature for operation | -20…60 °C |
Ambient air temperature for storage | -40…70 °C |
IP degree of protection | IP40 housing: conforming to IEC 60529 IP50 front face: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529 |
Pollution degree | 3 conforming to IEC 60664-1 |
Vibration resistance | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 15 gn not operating for 11 ms conforming to IEC 60068-2-27 5 gn in operation for 11 ms conforming to IEC 60068-2-27 |
Relative humidity | 95 % at 25…55 °C |
Electromagnetic compatibility | Fast transients immunity test – test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 Surge immunity test – test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Surge immunity test – test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Electrostatic discharge – test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge – test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test – test level: 10 V/m level 3 (80 MHz…1 GHz) conforming to IEC 61000-4-3 Conducted RF disturbances – test level: 10 V level 3 (0.15…80 MHz) conforming to IEC 61000-4-6 Fast transient bursts – test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 Immunity to microbreaks and voltage drops – test level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops – test level: 100 % (20 ms) conforming to IEC 61000-4-11 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 2.6 cm |
Package 1 Width | 8.2 cm |
Package 1 Length | 9.5 cm |
Package 1 Weight | 99.0 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 40 |
Package 2 Height | 15.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 4.532 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 640 |
Package 3 Height | 60.0 cm |
Package 3 Width | 80.0 cm |
Package 3 Length | 60.0 cm |
Package 3 Weight | 79.78 kg |
Produk Terkait
INBOW DUS WEJ5911 WS PANASONIC
Rp3.469
OUTBOW DOOS AC WBJ6010 WS PANASONIC
Rp17.678
OUTBOW DUS 4101 GRACIO BROCO CREAM
Rp10.674
OUTBOW DUS SCHNEIDER E238 MOUNTING BOX W/O TERM
Rp25.090
SAKLAR DOUBLE GRACIO BROCO 4162 2G 1W WHITE
Rp25.689
STOP KONTAK AC GRACIO BROCO 4155 WHITE
Rp45.493
STOP KONTAK ARDE GRACIO BROCO 4151 1G CREAM
Rp18.929
STOP KONTAK TV BROCO GALLEO G183-55S WHITE
Rp48.407