Deskripsi
Item Specification
Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 231.0 mm (1.72 in. x 17.40 in. x 9.09 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 115 mm × 545 mm × 360 mm (4.53 in. x 21.46 in. x 14.17 in.)
Chassis height [U] 1 U
Weight without packaging [kg(lb)] 3.4 kg (7.5 lb)
Weight with packaging [kg(lb)] 4.65 kg (10.25 lb)
Typical power consumption [W] 186 W
Typical heat dissipation [BTU/hour] 634.65 BTU/hour
Maximum power consumption [W] 253 W
Maximum heat dissipation [BTU/hour] 863.26 BTU/hour
MTBF [year] 54.68 year
MTTR [hour] 2 hour
Availability >0.99999
Noise at normal temperature (acoustic power) [dB(A)] 64.5 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 51.7 dB(A)
Number of card slots 0
Number of power slots 2
Number of fans modules 3
Redundant power supply 1+1

Pluggable AC and DC power modules can be used together in the same switch.

Long-term operating temperature [°C(°F)] -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Devices cannot start when the temperature is lower than 0°C (32°F).

When the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F).

Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH] 5% to 95%, noncondensing
Long-term operating altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode Pluggable power supply
Rated input voltage [V]
  • AC input: 100 V AC to 240 V AC; 50/60 Hz
  • High-voltage DC input: 240 V DC
  • DC input: –48 V DC to –60 V DC
Input voltage range [V]
  • AC input: 90–290 V AC; 45–65 Hz
  • High-voltage DC input: 190 V DC to 290 V DC
  • DC input: -38.4 V DC to -72 V DC
Maximum input current [A] The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.
Memory 4 GB
Flash memory 2 GB in total. To view the available flash memory size, run the display version command.
Console port RJ45
Eth Management port RJ45
USB Supported
RTC Supported
RPS input Not supported
Service port surge protection [kV]
Power supply surge protection [kV]
  • AC power module configured: ±6 kV in differential mode, ±6 kV in common mode
  • DC power module configured: ±2 kV in differential mode, ±4 kV in common mode
Types of fans Built-in
Heat dissipation mode Heat dissipation with fan, intelligent fan speed adjustment
Airflow direction Air intake from left and front, air exhaustion from right
PoE Not supported
Certification EMC certification

Safety certification

Manufacturing certification